{"id":2002,"date":"2026-07-23T12:01:51","date_gmt":"2026-07-23T10:01:51","guid":{"rendered":"https:\/\/www.tfsoleodinamica.it\/services\/test-bench\/"},"modified":"2026-07-23T12:01:51","modified_gmt":"2026-07-23T10:01:51","slug":"test-bench","status":"publish","type":"page","link":"https:\/\/www.tfsoleodinamica.it\/en\/services\/test-bench\/","title":{"rendered":"Hydraulic test bench \u2013 Pump, motor and hose testing"},"content":{"rendered":"<style>.kb-row-layout-id2002_main > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id2002_main > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id2002_main > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);grid-template-columns:minmax(0, calc(20% - ((var(--global-kb-gap-md, 2rem) * 2 )\/3)))minmax(0, calc(55% - ((var(--global-kb-gap-md, 2rem) * 2 )\/3)))minmax(0, calc(25% - ((var(--global-kb-gap-md, 2rem) * 2 )\/3)));}.kb-row-layout-id2002_main > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id2002_main > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}}@media all and (max-width: 1024px){.kb-row-layout-id2002_main > .kt-row-column-wrap{grid-template-columns:repeat(3, minmax(0, 1fr));}}@media all and (max-width: 767px){.kb-row-layout-id2002_main > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}.kb-row-layout-id2002_main > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id2002_main alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-3-columns kt-row-layout-custom kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column2002_col_nav > .kt-inside-inner-col{border-top-width:0px;border-right-width:0px;border-bottom-width:0px;border-left-width:0px;}.kadence-column2002_col_nav > .kt-inside-inner-col,.kadence-column2002_col_nav > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column2002_col_nav > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column2002_col_nav > .kt-inside-inner-col{flex-direction:column;}.kadence-column2002_col_nav > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column2002_col_nav > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column2002_col_nav{position:relative;}@media all and (max-width: 1024px){.kadence-column2002_col_nav > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column2002_col_nav > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column2002_col_nav tfs-service-nav-col\"><div class=\"kt-inside-inner-col\">\n\n<h4 class=\"wp-block-heading has-text-align-center\" style=\"color:#305473;\">Our Services<\/h4>\n\n\n\n<ul class=\"wp-block-list tfs-service-nav-list\"><li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/pump-and-motor-repair\/\">Pump and motor repair<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/hagglunds-motor-repair\/\">H\u00e4gglunds motor repair<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/test-bench\/\">Test bench<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/design-of-hydraulic-systems\/\">System design<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/construction-of-hydroelectric-power-plants\/\">Construction of hydraulic power plants<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/overhaul-of-hydraulic-components\/\">Component overhauls<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/on-site-support\/\">On-site support<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/hydraulic-piping-systems\/\">Piping systems<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/commissioning\/\">Commissioning<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/scheduled-maintenance\/\">Scheduled maintenance<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/testing-and-certification\/\">Testing and certification<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/software-development\/\">Software development<\/a><\/li><\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"has-text-align-center has-small-font-size wp-block-paragraph\"><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/\">\u2190 All services<\/a><\/p>\n\n<\/div><\/div>\n\n<style>.kadence-column2002_col_main > .kt-inside-inner-col{border-top-width:0px;border-right-width:0px;border-bottom-width:0px;border-left-width:0px;}.kadence-column2002_col_main > .kt-inside-inner-col,.kadence-column2002_col_main > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column2002_col_main > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column2002_col_main > .kt-inside-inner-col{flex-direction:column;}.kadence-column2002_col_main > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column2002_col_main > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column2002_col_main{position:relative;}@media all and (max-width: 1024px){.kadence-column2002_col_main > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column2002_col_main > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column2002_col_main\"><div class=\"kt-inside-inner-col\">\n\n<p class=\"wp-block-paragraph\">The test bench is what separates a verified overhaul from a declared repair. A component that has been stripped, cleaned and reassembled may look fine: only a run under load shows whether it actually performs. <strong>TFS operates three benches<\/strong> \u2014 pumps, motors and cylinders, high-pressure hoses \u2014 and issues every customer the test report with the measured values.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Hydraulic pump test bench<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An <strong>original Bosch Rexroth<\/strong> unit, recertified periodically. This is the bench used to test piston, gear and vane pumps after overhaul, and to verify new pumps before commissioning.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody>\n<tr><td><strong>Maximum test pressure<\/strong><\/td><td>470 bar<\/td><\/tr>\n<tr><td><strong>Maximum flow<\/strong><\/td><td>600 l\/min<\/td><\/tr>\n<tr><td><strong>Installed power<\/strong><\/td><td>120 kW<\/td><\/tr>\n<tr><td><strong>Largest component testable<\/strong><\/td><td>pumps up to 500 l\/min (e.g. Bosch Rexroth A4VSO 500)<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Hydraulic motor and cylinder test bench<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Also an <strong>original Bosch Rexroth<\/strong> unit, periodically recertified. It tests axial and radial piston motors, orbital motors and cylinders. It is the bench that allows TFS to run large motors under load \u2014 machines many workshops can strip down but not verify.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody>\n<tr><td><strong>Maximum test pressure<\/strong><\/td><td>420 bar<\/td><\/tr>\n<tr><td><strong>Maximum flow<\/strong><\/td><td>74 l\/min<\/td><\/tr>\n<tr><td><strong>Installed power<\/strong><\/td><td>15 kW<\/td><\/tr>\n<tr><td><strong>Largest component tested<\/strong><\/td><td>H\u00e4gglunds MB84 \u2014 1,500 kg, 33,780 cm&#179;\/rev displacement, 35\/70 rpm<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Viking MB84<\/strong> is the size benchmark: a radial piston motor delivering roughly 538 Nm of torque for every bar of differential pressure \u2014 over 180,000 Nm at 350 bar. See the <a href=\"https:\/\/www.tfsoleodinamica.it\/en\/case-study\/hagglunds-viking-mb84-motor-overhaul\/\">case study of an MB84 overhaul on an offshore winch<\/a>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">High-pressure hose test bench<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A bench <strong>type-approved by O+P<\/strong> (code BC\/L2000) dedicated to testing assembled hoses: burst testing and leak verification. It is what allows TFS to certify hoses assembled in house, a recurring requirement in the marine sector and on systems subject to inspection.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody>\n<tr><td><strong>Maximum test pressure<\/strong><\/td><td>2,000 bar<\/td><\/tr>\n<tr><td><strong>Tests performed<\/strong><\/td><td>burst, tightness and leakage<\/td><\/tr>\n<tr><td><strong>Type approval<\/strong><\/td><td>O+P \u2014 bench code BC\/L2000<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">What is measured during testing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">On pumps and motors the bench records the full set of parameters describing the real condition of the component:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Flow<\/strong> \u2014 what the component actually delivers against its nominal rating<\/li>\n<li><strong>Pressure<\/strong> \u2014 behaviour under different load conditions<\/li>\n<li><strong>Temperature<\/strong> \u2014 heating in operation, an indicator of abnormal friction<\/li>\n<li><strong>Volumetric efficiency<\/strong> \u2014 the parameter that reveals internal wear before it becomes a failure<\/li>\n<li><strong>Internal leakage<\/strong> \u2014 losses between high and low pressure<\/li>\n<li><strong>Noise<\/strong> \u2014 often the first symptom the customer notices<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">The test report<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">At the end of testing the customer receives a <strong>complete test report<\/strong> listing every test performed and the values recorded. It is not a formality: it is what tells you <em>how<\/em> the component going back into the line performs, lets you compare it against the rating plate and gives an objective reference for later checks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is also why an overhaul with instrumented testing carries different weight from a repair without a final run: what comes back with the component is not a statement, but numbers.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently asked questions about testing<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Can a component not repaired by TFS be tested?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes. Bench testing can be requested as a standalone service, to verify the performance of a new component, of one repaired elsewhere, or of a unit suspected of degradation before refitting it to the system.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Which brands can be tested?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The benches are not tied to a single manufacturer: TFS tests components from Bosch Rexroth, Kawasaki, H\u00e4gglunds, Casappa, Danfoss, Parker and others, within the pressure and flow limits given above. This is the advantage of a <a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/overhaul-of-hydraulic-components\/\">multi-brand<\/a> centre over service tied to one brand.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the largest component TFS can test?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">On the pump bench, units up to 500 l\/min such as a Bosch Rexroth A4VSO 500. On the motor bench the benchmark is a 1,500 kg H\u00e4gglunds MB84. Beyond these sizes, testing is agreed case by case.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Are the benches certified?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The pump and motor benches are <strong>original Bosch Rexroth<\/strong> units, recertified periodically. The hose bench is <strong>type-approved by O+P<\/strong>, bench code BC\/L2000.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Related services<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/pump-and-motor-repair\/\">Hydraulic pump and motor repair<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/overhaul-of-hydraulic-components\/\">Overhaul of hydraulic components<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/testing-and-certification\/\">Testing and certification<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/hydraulic-piping-systems\/\">Hydraulic piping systems<\/a><\/li>\n<li><a href=\"https:\/\/www.tfsoleodinamica.it\/en\/services\/hagglunds-motor-repair\/\">H\u00e4gglunds motor repair<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">To have a component tested, contact the TFS technical team with the part designation and rating plate data: <a href=\"https:\/\/www.tfsoleodinamica.it\/en\/contact-us\/\">request an assessment<\/a>.<\/p>\n\n\n\n<\/div><\/div>\n\n<style>.kadence-column2002_col_sidebar > .kt-inside-inner-col{border-top-width:0px;border-right-width:0px;border-bottom-width:0px;border-left-width:0px;}.kadence-column2002_col_sidebar > .kt-inside-inner-col,.kadence-column2002_col_sidebar > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column2002_col_sidebar > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column2002_col_sidebar > .kt-inside-inner-col{flex-direction:column;}.kadence-column2002_col_sidebar > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column2002_col_sidebar > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column2002_col_sidebar{position:relative;}@media all and (max-width: 1024px){.kadence-column2002_col_sidebar > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column2002_col_sidebar > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column2002_col_sidebar tfs-partner-sidebar\" id=\"tfs-partner-form\"><div class=\"kt-inside-inner-col\">\n\n<h4 class=\"wp-block-heading has-text-align-center\" style=\"color:#305473;\">Contact our specialist<\/h4>\n\n<div class=\"wp-block-image tfs-referente-photo\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"491\" height=\"491\" src=\"https:\/\/www.tfsoleodinamica.it\/wp-content\/uploads\/2026\/04\/Angelo-Pagano-4_1.png\" alt=\"Angelo Pagano - TFS Oleodinamica\" class=\"wp-image-268\" style=\"width:80px\" srcset=\"https:\/\/www.tfsoleodinamica.it\/wp-content\/uploads\/2026\/04\/Angelo-Pagano-4_1.png 491w, https:\/\/www.tfsoleodinamica.it\/wp-content\/uploads\/2026\/04\/Angelo-Pagano-4_1-300x300.png 300w, https:\/\/www.tfsoleodinamica.it\/wp-content\/uploads\/2026\/04\/Angelo-Pagano-4_1-150x150.png 150w\" sizes=\"auto, (max-width: 491px) 100vw, 491px\" \/><\/figure>\n<\/div>\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Angelo Pagano<\/strong><br>Owner and Technical Director<\/p>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">&#9742; <a href=\"tel:+390828301272\">+39 0828 301 272<\/a><br>Customer support<\/p>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">&#128241; <a href=\"tel:+393356533420\">+39 335 653 3420<\/a><br>Technical support<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<h4 class=\"wp-block-heading has-text-align-center\">Request a quotation<\/h4>\n\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f266-o1\" lang=\"it-IT\" dir=\"ltr\" data-wpcf7-id=\"266\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en\/wp-json\/wp\/v2\/pages\/2002#wpcf7-f266-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Modulo di contatto\" enctype=\"multipart\/form-data\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"266\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.1.6\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"it_IT\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f266-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<div class=\"wpcf7-turnstile cf-turnstile\" data-sitekey=\"0x4AAAAAAD1BkBh118TOx3WE\" data-response-field-name=\"_wpcf7_turnstile_response\"><\/div>\n\n<div class=\"tfs-cf7-sidebar\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"nome\" autocomplete=\"name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Full name *\" value=\"\" type=\"text\" name=\"nome\" autocomplete=\"name\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"email\" autocomplete=\"email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email *\" value=\"\" type=\"email\" name=\"email\" autocomplete=\"email\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"telefono\" autocomplete=\"tel\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-text wpcf7-validates-as-tel\" aria-invalid=\"false\" placeholder=\"Phone\" value=\"\" type=\"tel\" name=\"telefono\" autocomplete=\"tel\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"messaggio\" autocomplete=\"off\"><textarea cols=\"40\" rows=\"3\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"Message\" name=\"messaggio\" autocomplete=\"off\"><\/textarea><\/span><br \/>\n<label class=\"tfs-cf7-file-label\">Attach a photo or document (jpg, png, pdf, doc \u2013 max 10MB)<\/label><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"allegato\"><input size=\"40\" class=\"wpcf7-form-control wpcf7-file\" accept=\".jpg,.jpeg,.png,.pdf,.doc,.docx\" aria-invalid=\"false\" type=\"file\" name=\"allegato\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"privacy\"><span class=\"wpcf7-form-control wpcf7-acceptance\"><span class=\"wpcf7-list-item\"><label><input type=\"checkbox\" name=\"privacy\" value=\"1\" aria-invalid=\"false\" \/><span class=\"wpcf7-list-item-label\">I have read the <a href=\"\/en\/privacy-policy\/\" target=\"_blank\" rel=\"noopener\">privacy notice<\/a> and understand that the data entered will be processed by Tfs Tecno Fluid Service s.r.l. to reply to my request. Providing the necessary data is required in order to receive a reply.<\/span><\/label><\/span><\/span><\/span><br \/>\n<span id=\"wpcf7-6a6935cf55311-wrapper\" class=\"wpcf7-form-control-wrap honeypot-266-wrap\" data-cf7apps-honeypot=\"honeypot-266\" style=\"display: block;\n\t\t    width: 0px;\n\t\t    height: 0px;\n\t\t    padding: 0px;\n\t\t    border: 1px solid transparent;\n\t\t    display: block;\n\t\t    overflow: hidden;\n\t\t    \"><input type=\"hidden\" name=\"honeypot-266-random-hash\" value=\"17722485\"><label\n\t\t    for=\"wpcf7-6a6935cf55311-field\"\n\t\t    class=\"hp-message\"\n        >Si prega di lasciare vuoto questo campo.<\/label><input\n\t    id=\"wpcf7-6a6935cf55311-field\"\n\t    \n\t    class=\"wpcf7-form-control wpcf7-text\"\n\t    type=\"text\"\n\t    name=\"o4r2tmyotmwv\"\n\t    value=\"\"\n\t    size=\"40\"\n\t    autocomplete=\"new-password\"\n\t    tabindex=\"1000\"\n    \/><\/span><br \/>\n<input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Send request \u2192\" \/>\n\t<\/p>\n<\/div><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"647\" height=\"152\" src=\"https:\/\/www.tfsoleodinamica.it\/wp-content\/uploads\/2026\/04\/00-TFS_Kawasaki_Rexroth.png\" alt=\"TFS Bosch Rexroth + Kawasaki\" class=\"wp-image-290\" style=\"width:140px\" srcset=\"https:\/\/www.tfsoleodinamica.it\/wp-content\/uploads\/2026\/04\/00-TFS_Kawasaki_Rexroth.png 647w, https:\/\/www.tfsoleodinamica.it\/wp-content\/uploads\/2026\/04\/00-TFS_Kawasaki_Rexroth-300x70.png 300w\" sizes=\"auto, (max-width: 647px) 100vw, 647px\" \/><\/figure>\n<\/div>\n\n<p class=\"has-text-align-center has-small-font-size wp-block-paragraph\" style=\"color:#305473;font-weight:600;\">Certified test bench<br>Bosch Rexroth<\/p>\n\n\n<p class=\"has-text-align-center has-small-font-size wp-block-paragraph\"><strong>Authorized Service Centre Kawasaki<\/strong><\/p>\n\n\n<p class=\"has-text-align-center has-small-font-size wp-block-paragraph\">ISO 9001 Bureau Veritas since 1999<\/p>\n\n<\/div><\/div>\n\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>The test bench is what separates a verified overhaul from a declared repair. A component that has been stripped, cleaned and reassembled may look fine: only a run under load shows whether it actually performs. TFS operates three benches \u2014 pumps, motors and cylinders, high-pressure hoses \u2014 and issues every customer the test report with&#8230;<\/p>\n","protected":false},"author":0,"featured_media":0,"parent":1112,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"normal","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"class_list":["post-2002","page","type-page","status-publish","hentry"],"acf":[],"taxonomy_info":[],"featured_image_src_large":false,"author_info":{"display_name":"","author_link":"https:\/\/www.tfsoleodinamica.it\/en\/author\/"},"comment_info":0,"_links":{"self":[{"href":"https:\/\/www.tfsoleodinamica.it\/en\/wp-json\/wp\/v2\/pages\/2002","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tfsoleodinamica.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.tfsoleodinamica.it\/en\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tfsoleodinamica.it\/en\/wp-json\/wp\/v2\/comments?post=2002"}],"version-history":[{"count":0,"href":"https:\/\/www.tfsoleodinamica.it\/en\/wp-json\/wp\/v2\/pages\/2002\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.tfsoleodinamica.it\/en\/wp-json\/wp\/v2\/pages\/1112"}],"wp:attachment":[{"href":"https:\/\/www.tfsoleodinamica.it\/en\/wp-json\/wp\/v2\/media?parent=2002"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}